Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: High
-
Resolution: Fixed
-
Affects Version/s: None
-
Fix Version/s: VOLTHA v2.3
-
Labels:
-
Story Points:3
-
Epic Link:
1. Start kind-voltha (voltha up)
2. Run test from voltha-system-tests repo make sanity-kind. it should work
3. Run the test again make sanity-kind, it will likely fail
There are lots of different failure modes, and it seems the reason for this is there are lots of underlying bugs that are triggered nondeterministically. Take a look at the Issue Links for more details.
- is blocked by
-
VOL-2342 State cleanup in BBSim after OLT delete
- Resolved
-
VOL-2343 dhcpl2relay-allocations not removed
- Resolved
-
VOL-2437 Leftover state in etcd after OLT device deleted
- Resolved
- relates to
-
VOL-2344 OLT left in device list after delete, but not found when attempting to delete
- Resolved
-
VOL-2401 rw-core errors when deleting OLT
- Resolved
-
VOL-2402 Errors in openolt-adapter logs when OLT deleted
- Resolved
# | Subject | Branch | Project | Status | CR | V |
---|---|---|---|---|---|---|
16140,7 | [VOL-2231] Cleaning the packet-in/out logs and dumping packets in HEX | master | voltha-go | Status: MERGED | +2 | +1 |
16240,2 | [VOL-2231] Cleaning the packet-in/out logs and dumping packets in HEX | master | voltha-openolt-adapter | Status: MERGED | +2 | +1 |
16695,7 | VOL-1977 Run tests multiple times | master | ci-management | Status: MERGED | +2 | +1 |
16742,2 | VOL-1977 Workaround another bug in ONOS aaa app | master | ci-management | Status: MERGED | +2 | +1 |
16954,2 | VOL-1977 Modify back-to-back sanity test to use more ONUs | master | ci-management | Status: MERGED | +2 | +1 |
17085,1 | VOL-1977 Recent bug fixes eliminate need for some workarounds | master | ci-management | Status: MERGED | +2 | +1 |
17116,2 | VOL-1977 Remove workarounds from pipelines | master | ci-management | Status: MERGED | +2 | +1 |