Uploaded image for project: 'VOLTHA'
  1. VOLTHA
  2. VOL-4529

rw-core - ONU adapter does not receive ONU forced delete in case of OLT deletion

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Resolved (View Workflow)
    • Priority: Medium
    • Resolution: Fixed
    • Affects Version/s: VOLTHA v2.9, VOLTHA v2.10
    • Fix Version/s: VOLTHA v2.10
    • Component/s: rw-core
    • Labels:
      None

      Description

      For an ONU that is currently in reconciling mode after a restart of the ONU adapter, no RPC delete-device is sent in the present case if the processing of the deletion of the associated OLT starts shortly after the reconciling process has started.

      Timestamps in component log of test run https://jenkins.opencord.org/view/All%20Jobs/job/periodic-voltha-openonu-go-test-bbsim/774/

      • ONU reconciling at the ONU adapter starts at: 22:19:44.619
      • OLT deletion processing at rw-core starts at: 22:19:44.633

        Attachments

        1. OltDeletionAfterAdapterRestartOnuGo-combined.log.gz
          534 kB
          Holger Hildebrandt
        No reviews matched the request. Check your Options in the drop-down menu of this sections header.

          Activity

            People

            Assignee:
            hichawla Himani Chawla
            Reporter:
            HolgerH Holger Hildebrandt
            Watchers:
            4 Start watching this issue

              Dates

              Created:
              Updated:
              Resolved:

                Gerrit Reviews

                There are no open Gerrit changes