Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: Medium
-
Resolution: Fixed
-
Affects Version/s: VOLTHA v2.9, VOLTHA v2.10
-
Fix Version/s: VOLTHA v2.10
-
Component/s: rw-core
-
Labels:None
-
Story Points:2
-
Epic Link:
For an ONU that is currently in reconciling mode after a restart of the ONU adapter, no RPC delete-device is sent in the present case if the processing of the deletion of the associated OLT starts shortly after the reconciling process has started.
Timestamps in component log of test run https://jenkins.opencord.org/view/All%20Jobs/job/periodic-voltha-openonu-go-test-bbsim/774/
- ONU reconciling at the ONU adapter starts at: 22:19:44.619
- OLT deletion processing at rw-core starts at: 22:19:44.633