Uploaded image for project: 'VOLTHA'
  1. VOLTHA
  2. VOL-3986

BBSIM does not answer gemportnetworkctpperformancemonitoringhistorydata get

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Resolved (View Workflow)
    • Priority: Medium
    • Resolution: Cannot Reproduce
    • Affects Version/s: VOLTHA v2.8
    • Fix Version/s: None
    • Component/s: bbsim
    • Labels:
    • Environment:

      Detected by Torsten in his preliminary tests towards the PM robot test case.

      Description

      BBSIM receives according get requests (after the ME was created) from OnuAdapter.

      Receiving such GetRequest message on BBSIM is mapped to following error output:

      time="2021-04-08T07:04:16.367572072Z" level=error msg=cannot-Serialize-Onu2gResponse Err="attribute not found: 'IntervalEndTime'" TxID=81fc module=OMCI

       

      The according OnuAdapter OMCI message was (in this case):

      81fc490a01550400f20000000000000000000000000000000000000000000000000000000000000000000028

      Looks to me as if the message is mapped onto the wrong ME.

        Attachments

          Activity

            People

            Assignee:
            teone Matteo Scandolo
            Reporter:
            michaelpag Michael Pagenkopf
            Watchers:
            4 Start watching this issue

              Dates

              Created:
              Updated:
              Resolved:

                Gerrit Reviews

                There are no open Gerrit changes