Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: Medium
-
Resolution: Cannot Reproduce
-
Affects Version/s: VOLTHA v2.8
-
Fix Version/s: None
-
Component/s: bbsim
-
Labels:
-
Environment:
Detected by Torsten in his preliminary tests towards the PM robot test case.
-
Story Points:1
-
Epic Link:
BBSIM receives according get requests (after the ME was created) from OnuAdapter.
Receiving such GetRequest message on BBSIM is mapped to following error output:
time="2021-04-08T07:04:16.367572072Z" level=error msg=cannot-Serialize-Onu2gResponse Err="attribute not found: 'IntervalEndTime'" TxID=81fc module=OMCI
The according OnuAdapter OMCI message was (in this case):
81fc490a01550400f20000000000000000000000000000000000000000000000000000000000000000000028
Looks to me as if the message is mapped onto the wrong ME.
# | Subject | Branch | Project | Status | CR | V |
---|---|---|---|---|---|---|
24199,2 | [VOL-3986] Correctly serializing GemPortNetworkCtpPerformanceMonitoringHistoryData ME in GetResponse | master | bbsim | Status: MERGED | +2 | +1 |