Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: Medium
-
Resolution: Fixed
-
Affects Version/s: None
-
Fix Version/s: VOLTHA v2.3
-
Component/s: Testing
-
Labels:
-
Story Points:5
-
Epic Link:
There is another intermittent problem that is seen with "master".
Pings are failing sometimes even after a successful authentication and DHCP.
This issue is seen randomly on several tests. Logs can be found on failed tests here as an example
OLT Reboot test has the issue
# | Subject | Branch | Project | Status | CR | V |
---|---|---|---|---|---|---|
18207,6 | [VOL-2801] : readIndication routine going in an infinite loop on delete device. This is part of many fixes to come while debugging intermittent issues seen where auth/dhcp/ping fail sometimes in various scenarios. | master | voltha-openolt-adapter | Status: MERGED | +2 | +1 |
18225,2 | [VOL-2801] : Following OLT reboot, the readIndication receive stream would have already stopped. Sending a stop signal again, would cause subsequent readIndication invocation to immediately stop. We need to first check if the readIndication is running before sending a stop signal | master | voltha-openolt-adapter | Status: MERGED | +2 | +1 |