Type: Story
-
Status: Resolved (View Workflow)
-
Priority: High
-
Resolution: Done
-
Affects Version/s: None
-
Fix Version/s: VOLTHA v2.3
-
Component/s: onos-dhcpl2relay, onos-olt
-
Labels:
-
Story Points:2
-
Epic Link:
onos olt app need to behave according to the following description:
purgeOnDisconnection should be set to False.
When DEVICE_AVALIABILITY_CHANGED event arrived and is “DOWN” and Device Ports = 0 (all UNI as well as NNI ports have been already issued a PORT_REMOVED)
Call the “purgeFlowRules’ api of the FlowRuleService to purge the flow store
- relates to
-
VOL-2404 Issues with OLT hard Reboot (Physical reboot)
- Resolved
# | Subject | Branch | Project | Status | CR | V |
---|---|---|---|---|---|---|
18040,1 | [VOL-2744] onos app changes for OLT reboot | master | olt | Status: MERGED | +2 | +1 |
18041,1 | [VOL-2744] onos app changes for OLT reboot | master | dhcpl2relay | Status: MERGED | +2 | +1 |
18064,4 | [VOL-2744] on device reconnection do not reprovision eapol on existing subscriber | master | olt | Status: MERGED | +2 | +1 |