-
Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: Medium
-
Resolution: Fixed
-
Affects Version/s: None
-
Fix Version/s: VOLTHA v2.12
-
Component/s: openonu-adapter
-
Labels:None
-
Story Points:1
Currently, AlarmMgr at OpenOnuAdapterGo gets into a faulty state with continous Audit/Resynchronise/Audit loop during the following scenarios.
1)When some of the vendor ONTs report unconfigured MEs (For Instance , during testing ONT has responded with VoipConfigDataME Alarm Bit Map when the ONT is not configured for voice path).
2)The ONU-G ME currently doesn't have the defined Alarm Bit Map. Hence, reporting of alarms on that ME causes AlarmMgr to get into a loop state.
3)The MEs as created by OLT as per G984.4 standard are not part of ONU DB and hence the Alarms reported are not handled for these MEs.