Type: Sub-task
-
Status: To Do (View Workflow)
-
Priority: Low
-
Resolution: Unresolved
-
Affects Version/s: None
-
Fix Version/s: None
-
Component/s: ci-system
-
Labels:
-
Story Points:1
Job eventually failed due to a missing ethernet device but testing did not seem to react quickly and instead may have manifested farther downstream.
Figure out what happened, my suspicion would be an open/read call is not testing for failure status.
[2022-09-19T03:06:52.877Z] ------------------------------------------------------------------------------
[2022-09-19T03:06:52.877Z] Test Disable and Enable OLT for DT :: Validates E2E Ping Connectiv... /bin/sh: 1: /home/jenkins/.volt/config-minimal: Permission denied
[2022-09-19T03:11:56.669Z] | PASS |
[2022-09-19T03:11:56.669Z] ------------------------------------------------------------------------------
[2022-09-19T03:20:07.685Z] Test Delete and ReAdd OLT for DT :: Validates E2E Ping Connectivit... | PASS |
[2022-09-19T03:20:07.685Z] ------------------------------------------------------------------------------
[2022-09-19T03:20:36.630Z] Test Disable ONUs and OLT Then Delete ONUs and OLT for DT :: On de... /bin/sh: 1: /home/jenkins/.volt/config-minimal: Permission denied
[2022-09-19T03:29:05.085Z] | PASS |
[2022-09-19T03:29:05.085Z] ------------------------------------------------------------------------------
[2022-09-19T03:35:27.373Z] Test Disable and Enable OLT PON Port for DT :: Validates E2E Ping ... | PASS |
[2022-09-19T03:35:27.373Z] ------------------------------------------------------------------------------
[2022-09-19T03:41:32.713Z] Voltha DT PODTests :: Test various end-to-end scenarios | PASS |
[2022-09-19T03:41:32.713Z] 9 critical tests, 9 passed, 0 failed
[2022-09-19T03:41:32.713Z] 9 tests total, 9 passed, 0 failed
[2022-09-19T03:41:32.713Z] ==============================================================================