Uploaded image for project: 'VOLTHA'
  1. VOLTHA
  2. VOL-4774

openonuAdapterGo: Panic during scale test

    XMLWordPrintable

    Details

      Description

      During the scale tests with voltha-2.10 at ADTRAN a panic occured in the openonu-go adapter. This is a consequential error due to permanently disrupted OMCI communication caused by problems with the communication path via the OLT. The go collection routines started by the metrics collector ignore the permanently disturbed OMCI communication and try to query the metrics again and again until a panic is finally triggered by access to the adapter's resources that are no longer available (see logs attached).

        Attachments

          Issue Links

          No reviews matched the request. Check your Options in the drop-down menu of this sections header.

            Activity

              People

              Assignee:
              pnalmas Praneeth Nalmas
              Reporter:
              HolgerH Holger Hildebrandt
              Watchers:
              3 Start watching this issue

                Dates

                Created:
                Updated:
                Resolved:

                  Gerrit Reviews

                  There are no open Gerrit changes