Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: Medium
-
Resolution: Fixed
-
Affects Version/s: None
-
Fix Version/s: VOLTHA v2.9
-
Component/s: openonu-adapter
-
Labels:None
-
Story Points:2
-
Epic Link:
In the logs of test case "Reconcile in OMCI-Flows-Pushed" in DT workflow it can be seen that
reconciling of ONU falls back from status success to falied after reconciling timeout expires.
https://jenkins.opencord.org/view/All%20Jobs/job/periodic-voltha-multiple-olts-openonu-go-test-bbsim/704
# | Subject | Branch | Project | Status | CR | V |
---|---|---|---|---|---|---|
29791,1 | [VOL-4525] openonuAdapterGo - reconciling of ONU falls back from status success to falied | master | voltha-openonu-adapter-go | Status: MERGED | +2 | +1 |
30084,1 | [VOL-4525] openonuAdapterGo - reconciling of ONU falls back from status success to falied [VOL-4533] openonuAdapterGo - sporadically uni ports are missing after reconcile test | voltha-2.8 | voltha-openonu-adapter-go | Status: MERGED | +2 | +1 |