-
Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: Medium
-
Resolution: Done
-
Affects Version/s: VOLTHA v2.8, VOLTHA v2.9
-
Fix Version/s: VOLTHA v2.8, VOLTHA v2.9
-
Component/s: openonu-adapter
-
Labels:None
-
Environment:
Test with multi UNI and multi ONU.
-
Story Points:2
-
Epic Link:
Sporadically Voltha does not supply the expected device reason in case many parallel requests are done to update the device reason.
Observed eg. here in some POD testing with multiple UNI/multiple ONU at DisableEnableOlt test here:
https://jenkins.opencord.org/view/VOLTHA-2.X-Tests/job/periodic-voltha-multi-uni-multiple-olts-test-bbsim/154/artifact/functional-multiuni-multiolt-att