Uploaded image for project: 'VOLTHA'
  1. VOLTHA
  2. VOL-4400

ONU Upgrade abort not correctly processed when downloading under certain (state) conditions

    XMLWordPrintable

    Details

      Description

      The ongoing download to the ONU is sometimes not correctly aborted if requested.
      The error appears when the ONU upgrade FSM is in specific states that currently use loops or are waiting for events to return from the enterStateXxx function.
      In the end aborting is obviously done but maybe with some unneeded delay (and misleading log entries).
      The correction was already supplied to R2.8 (where this was first detected) in this gerrit Review:
      https://gerrit.opencord.org/c/voltha-openonu-adapter-go/+/28170.
      According changes must be merged to the master version now.

        Attachments

        No reviews matched the request. Check your Options in the drop-down menu of this sections header.

          Activity

            People

            Assignee:
            michaelpag Michael Pagenkopf
            Reporter:
            michaelpag Michael Pagenkopf
            Watchers:
            1 Start watching this issue

              Dates

              Created:
              Updated:
              Resolved:

                Gerrit Reviews

                There are no open Gerrit changes