Uploaded image for project: 'VOLTHA'
  1. VOLTHA
  2. VOL-4346

On OLT reboot, ONUs are cleared from etcd but not ONU related ports

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Resolved (View Workflow)
    • Priority: High
    • Resolution: Done
    • Affects Version/s: VOLTHA v2.8
    • Fix Version/s: VOLTHA v2.9
    • Component/s: rw-core
    • Labels:
      None
    • Story Points:
      5

      Description

      On OLT reboot, the existing ONUs are deleted, but the etcd data related to the ONU ports are not cleared. Please look into the attached files for more information

        Attachments

          Issue Links

          No reviews matched the request. Check your Options in the drop-down menu of this sections header.

            Activity

              People

              Assignee:
              serkantul Serkant Uluderya
              Reporter:
              aghosh Amit Ghosh
              Watchers:
              2 Start watching this issue

                Dates

                Created:
                Updated:
                Resolved:

                  Gerrit Reviews

                  There are no open Gerrit changes