-
Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: Medium
-
Resolution: Done
-
Affects Version/s: None
-
Fix Version/s: VOLTHA v2.8, VOLTHA v2.9
-
Component/s: omci-lib-go, openonu-adapter
-
Labels:None
-
Story Points:1
The 11/2017 version of ITU G.988 has several class ID values that are off by one from where the should be. This primarily affects the Ethernet Extended PM 64-bit counters since the incorrect value (426) maps to a different (and valid) ME on most ONUs.
The value should be 425. The other affected MEs are related to EFM Bonding group but should be corrected as well.
NOTE: A unit test will be added to insure that the 426 for this ME does not creep back into the code since this is from code-generated code. Work on parsing the 03/2020 version of G.988 is underway as well.