Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: Low
-
Resolution: Cannot Reproduce
-
Affects Version/s: None
-
Fix Version/s: VOLTHA v2.8
-
Component/s: openonu-adapter
-
Labels:
-
Story Points:1
-
Epic Link:
Sporidally a metric event of UNI-Satatus is missing, mainly in DT workflow, baut also seen in ATT workflow.
For issue please look at PM-Data pipeline https://jenkins.opencord.org/view/All%20Jobs/job/periodic-voltha-pm-data-test-bbsim/.
Example for DT workflow: [https://jenkins.opencord.org/view/All%20Jobs/job/periodic-voltha-pm-data-test-bbsim/44/
]Example for ATT workflow: https://jenkins.opencord.org/view/All%20Jobs/job/periodic-voltha-pm-data-test-bbsim/43/
Before error two further testcases runs successfully with a duration of more than 30 minutes. Mayb the issue belongs to setting the frequency of the metric event.
- is caused by
-
VOL-4199 PM-Data: Wrong oper_status and uni_admin_state in metric event UNI-Status for disabled onu device
- Resolved