Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: Blocker
-
Resolution: Done
-
Affects Version/s: None
-
Fix Version/s: VOLTHA v2.7
-
Component/s: bbsim
-
Labels:None
-
Story Points:3
-
Epic Link:
If the TechProfile is not 1 Tcont 1 GemPort the flows have a different format:
voltha/bbsim1-76556cf4cf-f5mn6[bbsim]: time="2021-03-22T12:07:53.002741115Z" level=error msg=invalid-flow-for-onu Flow="onu_id:2 flow_id:5395595953541645972 flow_type:\"upstream\" alloc_id:1024 classifier:<o_vid:901 o_pbits:255 eth_type:34958 pkt_tag_type:\"single_tag\" > action:<cmd:<trap_to_host:true > > priority:10000 cookie:53761721760988894 port_no:32 tech_profile_id:64 replicate_flow:true pbit_to_gemport:<key:0 value:1024 > pbit_to_gemport:<key:1 value:1025 > pbit_to_gemport:<key:2 value:1024 > pbit_to_gemport:<key:3 value:1025 > pbit_to_gemport:<key:4 value:1025 > pbit_to_gemport:<key:5 value:1026 > pbit_to_gemport:<key:6 value:1027 > pbit_to_gemport:<key:7 value:1027 > gemport_to_aes:<key:1024 value:true > gemport_to_aes:<key:1025 value:true > gemport_to_aes:<key:1026 value:true > gemport_to_aes:<key:1027 value:true > " IntfId=0 OnuId=2 SerialNumber=BBSM000b0002 err=gem-0-already-in-use-on-uni-16-onu-1 module=OLT
TheĀ GemportId is set to 0 and theĀ PbitToGemport map is populated, carrying the gemports used in that flow.