Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: Medium
-
Resolution: Done
-
Affects Version/s: None
-
Fix Version/s: VOLTHA v2.7
-
Component/s: bbsim
-
Labels:None
-
Story Points:2
-
Epic Link:
Reference: https://jenkins.opencord.org/view/VOLTHA-2.X-Tests/job/periodic-voltha-test-bbsim/670/console
BBSim Logs:
time="2021-03-22T07:44:12.765616768Z" level=info msg="Disabling OLT" module=OLT oltId=10 time="2021-03-22T07:44:12.766140709Z" level=debug msg="Changing PON Port OperState from up to down" ID=0 module=OLT time="2021-03-22T07:44:12.766262423Z" level=debug msg="Sent Indication_IntfInd for PON" IntfId=0 OperState=down module=OLT time="2021-03-22T07:44:12.766345692Z" level=debug msg="Sent Indication_IntfOperInd for PON" IntfId=0 OperState=down Type=pon module=OLT time="2021-03-22T07:44:12.766430561Z" level=debug msg="Changing ONU InternalState from enabled to pon_disabled" IntfId=0 OnuId=1 OnuSn=BBSM000a0001 module=ONU time="2021-03-22T07:44:12.766818129Z" level=debug msg="Changing OLT InternalState from enabled to disabled" module=OLT time="2021-03-22T07:44:12.766862909Z" level=debug msg="Changing OLT OperState from up to down" module=OLT time="2021-03-22T07:44:12.766946377Z" level=debug msg="Sent Indication_OltInd" OperState=down module=OLT time="2021-03-22T07:44:13.235203239Z" level=debug msg="OLT receives FlowRemove" AllocId=0 Cookie=0 FlowId=3531616319679945364 FlowType=upstream GemportId=0 IntfId=0 OnuId=0 PbitToGemport="map[]" PortNo=0 ReplicateFlow=false UniID=0 module=OLT time="2021-03-22T07:44:13.23609187Z" level=debug msg="ONU receives FlowRemove" FlowId=3531616319679945364 FlowType=upstream IntfId=0 OnuId=1 SerialNumber=BBSM000a0001 module=ONU time="2021-03-22T07:44:14.761407396Z" level=debug msg="OLT receives FlowRemove" AllocId=0 Cookie=0 FlowId=3350873832941902163 FlowType=upstream GemportId=0 IntfId=0 OnuId=0 PbitToGemport="map[]" PortNo=0 ReplicateFlow=false UniID=0 module=OLT time="2021-03-22T07:44:14.761665231Z" level=debug msg="ONU receives FlowRemove" FlowId=3350873832941902163 FlowType=upstream IntfId=0 OnuId=1 SerialNumber=BBSM000a0001 module=ONU time="2021-03-22T07:44:14.772214867Z" level=info msg="Received ReenableOlt request from VOLTHA" module=OLT oltId=10 time="2021-03-22T07:44:14.772327941Z" level=debug msg="Changing OLT InternalState from disabled to enabled" module=OLT time="2021-03-22T07:44:14.772377463Z" level=debug msg="Changing OLT OperState from down to up" module=OLT time="2021-03-22T07:44:14.772435808Z" level=debug msg="Sent Indication_OltInd" OperState=up module=OLT time="2021-03-22T07:44:14.772488147Z" level=debug msg="Changing PON Port OperState from down to up" ID=0 module=OLT time="2021-03-22T07:44:14.772548676Z" level=debug msg="Sent Indication_IntfInd for PON" IntfId=0 OperState=up module=OLT time="2021-03-22T07:44:14.773023452Z" level=debug msg="Sent Indication_IntfOperInd for PON" IntfId=0 OperState=up Type=pon module=OLT time="2021-03-22T07:44:14.773088436Z" level=debug msg="Changing PON Port InternalState from disabled to enabled" ID=0 module=OLT time="2021-03-22T07:44:14.773281514Z" level=error msg="Error enabling ONU" Err="event enabled does not exist" IntfId=0 OnuSn=BBSM000a0001 time="2021-03-22T07:44:14.939130642Z" level=debug msg="OLT receives FlowRemove" AllocId=0 Cookie=0 FlowId=5329169870015111227 FlowType=downstream GemportId=0 IntfId=0 OnuId=0 PbitToGemport="map[]" PortNo=0 ReplicateFlow=false UniID=0 module=OLT time="2021-03-22T07:44:14.939367944Z" level=debug msg="ONU receives FlowRemove" FlowId=5329169870015111227 FlowType=downstream IntfId=0 OnuId=1 SerialNumber=BBSM000a0001 module=ONU time="2021-03-22T07:44:15.014330255Z" level=debug msg="OLT receives FlowRemove" AllocId=0 Cookie=0 FlowId=4004578016902664512 FlowType=upstream GemportId=0 IntfId=0 OnuId=0 PbitToGemport="map[]" PortNo=0 ReplicateFlow=false UniID=0 module=OLT time="2021-03-22T07:44:15.014668384Z" level=debug msg="ONU receives FlowRemove" FlowId=4004578016902664512 FlowType=upstream IntfId=0 OnuId=1 SerialNumber=BBSM000a0001 module=ONU time="2021-03-22T07:44:15.014725753Z" level=info msg="Resetting GemPort" IntfId=0 OnuId=1 SerialNumber=BBSM000a0001 module=ONU time="2021-03-22T07:44:15.306736193Z" level=info msg="received RemoveTrafficQueues" module=OLT time="2021-03-22T07:44:15.30828905Z" level=info msg="received RemoveTrafficSchedulers" IntfId=0 OnuId=1 OnuPortNo=16 module=OLT time="2021-03-22T07:44:15.323349991Z" level=info msg="received RemoveTrafficQueues" module=OLT time="2021-03-22T07:44:15.325002716Z" level=info msg="received RemoveTrafficSchedulers" IntfId=0 OnuId=1 OnuPortNo=16 module=OLT time="2021-03-22T07:48:33.692617287Z" level=info msg="received CreateTrafficSchedulers" IntfId=0 OnuId=1 OnuPortNo=16 module=OLT time="2021-03-22T07:48:33.694466283Z" level=info msg="received CreateTrafficQueues" module=OLT time="2021-03-22T07:48:33.818938018Z" level=debug msg="OLT receives FlowAdd for ONU" AllocId=1024 ClassifierEthType=0 ClassifierIVid=0 ClassifierOPbits=255 ClassifierOVid=900 Cookie=53480247961381985 DstPort=0 FlowId=3350873832941902163 FlowType=upstream GemportId=1024 InnerVlan=0 IntfId=0 IpProto=0 OnuId=1 OnuSn=BBSM000a0001 OuterVlan=900 PbitToGemport="map[]" PortNo=16 ReplicateFlow=false SrcPort=0 UniID=0 module=ONU
# | Subject | Branch | Project | Status | CR | V |
---|---|---|---|---|---|---|
23633,2 | [VOL-3940] Using the correct transition when reactivating ONUs Cleaning ONU state when we enter pon_disabled state | master | bbsim | Status: MERGED | +2 | +1 |