Uploaded image for project: 'VOLTHA'
  1. VOLTHA
  2. VOL-3912

IGMP proxy hashes on wrong connect point

    XMLWordPrintable

    Details

      Description

      The current hash is done on the `connectPoint` object which is going to be the same because it's the uplink connect point. The hash should instead be done over the passed in `cp` which is the one on which the ONU is connected.