Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: Medium
-
Resolution: Fixed
-
Affects Version/s: VOLTHA v2.6
-
Fix Version/s: VOLTHA v2.7
-
Component/s: openolt-agent
-
Labels:None
-
Story Points:3
-
Epic Link:
The downstream BAL flow is missing pbit classifier (in this case it defaults to pbit-0). This issue is seen only in ATT workflow. This results in non-zero pbit traffic coming in downstream direction landing on a wrong gem-port which is subsequently dropped by the ONU.
The fix is to have the right pbit classifier in the dowsntream BAL flow for ATT workflow.
# | Subject | Branch | Project | Status | CR | V |
---|---|---|---|---|---|---|
22259,1 | VOL-3732: Non-zero pbit traffic dropped in the downstream direction for ATT workflow | master | openolt | Status: MERGED | +2 | +1 |