Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: Medium
-
Resolution: Fixed
-
Affects Version/s: VOLTHA v2.6
-
Fix Version/s: VOLTHA v2.7
-
Component/s: openolt-agent
-
Labels:None
-
Story Points:3
-
Epic Link:
The downstream BAL flow is missing pbit classifier (in this case it defaults to pbit-0). This issue is seen only in ATT workflow. This results in non-zero pbit traffic coming in downstream direction landing on a wrong gem-port which is subsequently dropped by the ONU.
The fix is to have the right pbit classifier in the dowsntream BAL flow for ATT workflow.