Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: Low
-
Resolution: Fixed
-
Affects Version/s: None
-
Fix Version/s: VOLTHA v2.7
-
Component/s: bbsim
-
Labels:None
-
Environment:
BBSIm testing
-
Story Points:1
-
Epic Link:
The padding of the DeleteResponse message looks quite strange, in a strict sense it is wrong.
As the error code position is still 0 it has no effect on message decoding at the OnuAdapter(go) decoding, but should be verified/corrected in the BBSIM implementation.
Exact observation: on delete Vlan tagging Filter data:
Request:
8148460a00542243000000000000000000000000000000000000000000000000000000000000000000000028
Response:
8148260a0054224300*0b000080*0000000000000000000000000000000000000000000000000000000000000000000000