Pings failed, as flows failed to get added in some scenarios

    XMLWordPrintable

    Details

      Description

      Pings are failing after a successful auth,subscriber provision and DHCP.

      According to analysis from Girish, flow additions fail on the OLT [when two subscribers get the same flow_id, flow fails to get added]

      https://jenkins.opencord.org/view/VOLTHA-2.X-Tests/job/build_onf-demo-pod_Default_voltha_2.3_test/4/robot/report/FailureScenarios/log.html

      OLT reboot -  Pings failed (for two ONUs) after rebooting and performing sanity test

      https://jenkins.opencord.org/view/VOLTHA-2.X-Tests/job/build_flex-ocp-cord_1T4GEM_voltha_2.3_test/7/robot/report/FailureScenarios/log.html 

      Pings failed on many tests here: ex: OLT Reboot, openolt restarts,  Radius restart tests will show the issue.