Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: Blocker
-
Resolution: Fixed
-
Affects Version/s: None
-
Fix Version/s: VOLTHA v2.3
-
Component/s: Testing
-
Labels:
-
Story Points:5
-
Epic Link:
Many tests are failing due to ping issues.
Pings fail as ONUs are stuck in "tech-profile-config-download-success".
Problem is not 100% reproducible, but seen frequently.
Issue is seen on 3 out of 5 test runs.
Logs can be found on these master jobs that are run on the QA hardware PODs. Please check logs on runs #205 #206 #208 here https://jenkins.opencord.org/view/VOLTHA-2.X-Tests/job/build_onf-demo-pod_Default_voltha_master_test/
# | Subject | Branch | Project | Status | CR | V |
---|---|---|---|---|---|---|
18149,6 | [VOL-2786] : Handle flow deletes completely before proceeding onto flow adds for a subscriber. Also serialize flow deletes on a per subscriber basis. Flow Adds are already serialized on a per subscriber basis. | master | voltha-openolt-adapter | Status: MERGED | +2 | +1 |
18163,2 | [VOL-2787] : When there is an active tech-profile task ongoing for an UNI port schedule new tech-profile tasks for same UNI for later execution. | master | voltha-openonu-adapter | Status: MERGED | +2 | +1 |
18171,1 | WIP VOL-2787: experimenting with flow removes/adds | master | voltha-openonu-adapter | Status: ABANDONED | 0 | +1 |