Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: Low
-
Resolution: Fixed
-
Affects Version/s: VOLTHA v2.2
-
Fix Version/s: VOLTHA v2.3
-
Component/s: onos-dhcpl2relay, onos-olt
-
Labels:
-
Story Points:5
-
Epic Link:
After a successful deletion of a OLT, all flows/ports pertaining to OLT and ONUs are cleaned up in the voltha. But there are several objects still shown in ONOS.
Check the logs below that show the lingering objects in ONOS for the subscribers/ONUs
Tested using hardware OLT, released and master images
Steps:
- Disable the OLT "voltctl device disable <olt id>"
- Delete the OLT "voltctl device delete <olt id>"
- Check in ONOS , output of the following commands "devices" , "dhcpl2relay-allocations", "aaa-users"
===========
onos> devices
id=of:0000000000000001, available=true, local-status=connected 1h11m ago, role=MASTER, type=SWITCH, mfr=Accton Corp., hw=x86-64-accton-as6712-32x-r0, sw=ofdpa 3.0.5.5+accton1.7-1, serial=671232X1538033, chassis=1, driver=ofdpa3, channelId=10.128.100.70:34341, locType=none, managementAddress=10.128.100.70, name=of:0000000000000001, protocol=OF_13
id=of:0000b86a97071b4a, available=false, local-status=disconnected 1m35s ago, role=NONE, type=SWITCH, mfr=VOLTHA Project, hw=open_pon, sw=open_pon, serial=EC1904000654, chassis=b86a97071b4a, driver=voltha, channelId=10.233.75.6:56482, managementAddress=10.233.75.6, protocol=OF_13
onos> aaa-users
UserName=user,CurrentState=AUTHORIZED,DeviceId=of:0000b86a97071b4a,MAC=90:E2:BA:8E:70:66,PortNumber=40976,SubscriberId=ALPHe3d1ced5-1
onos> volt-programmed-subscribers
onos> links
onos>
onos> ports -e
id=of:0000000000000001, available=true, local-status=connected 1h12m ago, role=MASTER, type=SWITCH, mfr=Accton Corp., hw=x86-64-accton-as6712-32x-r0, sw=ofdpa 3.0.5.5+accton1.7-1, serial=671232X1538033, chassis=1, driver=ofdpa3, channelId=10.128.100.70:34341, locType=none, managementAddress=10.128.100.70, name=of:0000000000000001, protocol=OF_13
port=1, state=enabled, type=fiber, speed=40000 , adminState=enabled, portMac=cc:37:ab:61:80:49, portName=port1
port=31, state=enabled, type=fiber, speed=40000 , adminState=enabled, portMac=cc:37:ab:61:80:49, portName=port31
id=of:0000b86a97071b4a, available=false, local-status=disconnected 2m43s ago, role=NONE, type=SWITCH, mfr=VOLTHA Project, hw=open_pon, sw=open_pon, serial=EC1904000654, chassis=b86a97071b4a, driver=voltha, channelId=10.233.75.6:56482, managementAddress=10.233.75.6, protocol=OF_13
onos>
ADDED, bytes=0, packets=0, table=60, priority=30000, selector=[ETH_TYPE:ipv6, IP_PROTO:58, ICMPV6_TYPE:133], treatment=[immediate=[OUTPUT:CONTROLLER]]
deviceId=of:0000b86a97071b4a, flowRuleCount=0
onos>
onos> dhcpl2relay-allocations
SubscriberId=ALPHe3d1cf9d-1,ConnectPoint=of:0000b86a97071b4a/32,State=DHCPACK,MAC=90:E2:BA:8E:70:64,CircuitId=None,IP Allocated=10.99.22.1,Allocation Timestamp=2019-12-11T03:19:56.681Z
SubscriberId=ALPHe3d1ced5-1,ConnectPoint=of:0000b86a97071b4a/40976,State=DHCPACK,MAC=90:E2:BA:8E:70:66,CircuitId=None,IP Allocated=10.99.33.1,Allocation Timestamp=2019-12-11T03:20:21.874Z
SubscriberId=BRCM22222222-1,ConnectPoint=of:0000b86a97071b4a/16,State=DHCPACK,MAC=90:E2:BA:8E:70:65,CircuitId=None,IP Allocated=10.99.11.6,Allocation Timestamp=2019-12-11T03:20:13.758Z
onos>
onos> volt-bpmeter-mappings
onos>