Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: High
-
Resolution: Cannot Reproduce
-
Affects Version/s: VOLTHA v2.1
-
Fix Version/s: VOLTHA v2.2
-
Component/s: api-server, bbsim, rw-core
-
Labels:
-
Story Points:5
-
Epic Link:
robot -v ONOS_REST_PORT:8181 -v ONOS_SSH_PORT:8101 --exclude notready --critical sanity -v num_onus:1 sanity.robot
==============================================================================
Sanity :: Creates bbsim olt/onu and validates activataion Assumes voltha-go...
==============================================================================
Activate Device BBSIM OLT/ONU :: Validate deployment -> create and... | FAIL |
Keyword 'Validate Device' failed after retrying for 4 minutes. The last error was: Device BBSM00000001 mib_state incorrect
------------------------------------------------------------------------------
Validate OLT Connected to ONOS :: Verifies the BBSIM-OLT device is... | PASS |
------------------------------------------------------------------------------
Check EAPOL Flows in ONOS :: Validates eapol flows for the onu are... | FAIL |
Keyword 'Verify Eapol Flows Added' failed after retrying for 4 minutes. The last error was: ' 1' does not contain '4'
------------------------------------------------------------------------------
Validate ONU Authenticated in ONOS :: Validates onu is AUTHORIZED ... | FAIL |
Keyword 'Verify Number of AAA-Users' failed after retrying for 4 minutes. The last error was: ' 0' does not contain '1'
------------------------------------------------------------------------------
Add Subscriber-Access in ONOS :: Through the olt-app in ONOS, exec... | PASS |
------------------------------------------------------------------------------
Validate DHCP Assignment in ONOS :: After IP Flows are pushed to t... | PASS |
------------------------------------------------------------------------------
Delete Device and Verify :: Disable -> Delete devices via voltctl ... | FAIL |
Variable '${onu_device_id}' not found.
------------------------------------------------------------------------------
Sanity :: Creates bbsim olt/onu and validates activataion Assumes ... | FAIL |
7 critical tests, 3 passed, 4 failed
7 tests total, 3 passed, 4 failed
==============================================================================