Type: Bug
-
Status: Resolved (View Workflow)
-
Priority: Medium
-
Resolution: Done
-
Affects Version/s: None
-
Fix Version/s: SEBA 2.0
-
Component/s: VOLTHA
-
Labels:None
-
Story Points:3
-
Epic Link:
Noticed that after a successful authentication and DHCP, pings are failing to RG.
Observed that flows "lldp" and "ipv4" on NNI port are missing in ONOS.
==========================================================
deviceId=of:000000000ac014ce, flowRuleCount=6
ADDED, bytes=0, packets=0, table=0, priority=10000, selector=[IN_PORT:16, ETH_TYPE:eapol], treatment=[immediate=[OUTPUT:CONTROLLER]]
ADDED, bytes=0, packets=0, table=0, priority=10000, selector=[IN_PORT:16, ETH_TYPE:ipv4, IP_PROTO:17, UDP_SRC:68, UDP_DST:67], treatment=[immediate=[OUTPUT:CONTROLLER]]
ADDED, bytes=0, packets=0, table=0, priority=1000, selector=[IN_PORT:65536, METADATA:3e700000010, VLAN_VID:111], treatment=[immediate=[VLAN_POP], transition=TABLE:1]
ADDED, bytes=0, packets=0, table=0, priority=1000, selector=[IN_PORT:16, VLAN_VID:0], treatment=[immediate=[VLAN_ID:999], transition=TABLE:1]
ADDED, bytes=0, packets=0, table=1, priority=1000, selector=[IN_PORT:65536, VLAN_VID:999], treatment=[immediate=[VLAN_POP, OUTPUT:16]]
ADDED, bytes=0, packets=0, table=1, priority=1000, selector=[IN_PORT:16, VLAN_VID:999], treatment=[immediate=[VLAN_PUSH:vlan, VLAN_ID:111, OUTPUT:65536]]