Case 1 - Fiber connecting the Ethernet switch to the PON unit fails and the in-band management also fails
- Ethernet switch reports: Loss of signal, port #
- PON device reports: Loss of signal, port #, through out of band connection since the in-band connection would be out of service in this case
- NEM reports: Loss of signal on switch port #, PON hardware feeder port #, service-affecting, and a list of customers affected by this condition
- NEM information: Retrieve historical alarms from the previous hour, day, etc. to look for telltale signs of failure
- NEM information: Retrieve historical syslogs from the previous hour, day, etc. to look for telltale signs of failure
- NEM information: Retrieve configuration of the Ethernet switch port and also the PON hardware uplink port
- blocks
-
SEBA-205 Unify the management interfaces of the SEBA pod parts
- To Do
# | Subject | Branch | Project | Status | CR | V |
---|---|---|---|---|---|---|
13358,15 | SEBA-206 manage and report switchport state | master | fabric | Status: MERGED | +2 | +1 |
13373,1 | SEBA-206 Publish ONOS fabric switch port events to kafka | master | kafka-onos | Status: MERGED | +2 | +1 |
13388,13 | SEBA-206 Report OLT link connectivity in OLTDevice model | master | olt-service | Status: MERGED | +2 | +1 |
13395,1 | SEBA-206 add requests_mock to venv | master | xos | Status: MERGED | +2 | +1 |
13504,7 | SEBA-206 add switch context to PORT_LOS alarm; add olt name to PORT_LOS alarm; rename alarm | master | olt-service | Status: MERGED | +2 | +1 |