Type: Bug
-
Status: To Do (View Workflow)
-
Priority: Medium
-
Resolution: Unresolved
-
Affects Version/s: None
-
Fix Version/s: None
-
Component/s: Fabric
-
Labels:
-
Story Points:3
-
Epic Link:
See attached topology graph: if we disable and reenable any port connecting to switch 225 from ONOS, the corresponding port on switch 225 remains disabled and won't come up unless we reset the port speed.
Example: if we disable and enable port 51 on switch 204 by
onos> portstate of:0000000000000204 51 disable onos> portstate of:0000000000000204 51 enable
The link goes down and never comes up because port 31 on the other end of this link, i.e. switch 225. stays in disabled state.
onos> ports of:0000000000000225 | grep 31 port=31, state=disabled, type=fiber, speed=40000 , adminState=enabled, portMac=cc:37:ab:7c:bc:7f, portName=port31
The port on switch 204 side is enabled correctly.
We can fix the problem by running "client_drivshell port 31 sp=40000" on the switch. However every port on the switch should be already 40G by default.
Before re-setting the port speed
Feb 4 23:18:43 localhost OFDPA[7927]: SDK: xe30( 31) down 40G FD SW No Forward Untag F CR4 9412
After re-setting the port speed
Feb 4 23:18:57 localhost OFDPA[7927]: SDK: xe30( 31) up 40G FD SW No Forward None F CR4 9412
More details:
ONOS version: 1.15
switch 225:
Vendor : Accton Corp.
H/W Version : x86-64-accton-as6712-32x-r0
S/W Version : ofdpa 1.1.7.2-premium+accton1.0-1
switch 204:
Vendor : Broadcom Ltd.
H/W Version : Accton AS5912-54x
S/W Version : OF-DPA Premium 1.1.5.6