      Description

      The AES calculation assumes the length of the data to calculate is 44 octets (what a baseline message set frame has) and does not properly support the extended message set which can easily be under 44 octets or >1900 octets long [should use the 'length' field].

      First seen in the decode of the following Start Software Download response frame:

      0003330b000700010002000712bb24e7

      AES is last 4 octets of the 16 octet frame above.